HRG Series 2

HRG Series 2

  • A neutral-grounding resistor with optional pulsing function
  • NGR-failure detection with NGRM700 or RC48N NGR monitors
  • Multi-feeder ground-fault detection with locating feature
  • Line-voltage monitoring with NGRM700
  • Front-panel information and programming displays
  • Standard network communications with COM465IP
  • Floor-mount control cabinet with top– or remote-mounted NGR enclosure

BHRG Series 2 HRG systems integrate a neutral-grounding resistor (NGR) assembly with pulsing function and NGR monitoring; individual ground-fault detection for up to 60 circuits with optional network communications via a COM465IP gateway or CP700 Gateway/HMI. Monitoring, display, and control components are housed in a floor-mount enclosure—the NGR assembly mounts on the control cabinet or at another location.

NGR monitoring is with an RC48N Ground-Fault & NGR Monitor or an NGRM700 Neutral-Grounding-Resistor Monitor. The former provides basic AC ground-fault and open-NGR detection. The latter adds AC/DC ground-fault detection, harmonic analysis, two ground-fault detection levels, NGR-short detection, phase-voltage monitoring, and a graphical user interface.

Bender RCMS460 or RCMS490 ground-fault monitors provide multiple-feeder monitoring to detect AC and DC faults in up to 12 circuits per device. The RCMS460 has common relay outputs; the RCMS490 adds dedicated relay outputs for each monitored channel (required for tripping systems). Each BHRG Series 2 unit can be configured with up to four RCMS monitors—48 circuits.

All variants include front-panel pilot lights to indicate control-voltage presence and relay-alarm state, and may include switches for test, reset, and pulse-enable functions. Lower feature/cost units with RC48N NGR Monitor can be equipped with analog gauges for front-panel neutral-voltage and -current indication.

Options include an audible alarm, portable pulsing and a neutral-disconnect switch

Bender Inside Sales team is available to assist with proper selection of CT’s for the feeders.

  • Features
  • Ordering information
  • Downloads
  • A neutral-grounding resistor with optional pulsing function
  • NGR-failure detection with NGRM700 or RC48N NGR monitors
  • Multi-feeder ground-fault detection with locating feature
  • Line-voltage monitoring with NGRM700
  • Front-panel information and programming displays
  • Standard network communications with COM465IP
  • Floor-mount control cabinet with top– or remote-mounted NGR enclosure

Variants of HRG Series 2


For assistance with ordering please contact Industrial.Sales@Bender-us.com or call (610) 383-9200.

Downloads for HRG Series 2

Category

Language

Category Product Language Size Download